reflow.gif (2518 bytes)

Click for larger image Click for larger image Click for larger image Click for larger image
INSIGHT FOR
REFLOW TRACKER

analysis software for
all electronics assembly profiling tasks including Reflow, Wave and
Vapour phase soldering
RAPID OVEN SETUP (ROS)
Let the software find
the optimum oven
recipe settings

SURVEYOR
easy to use fully automated process stability and capability monitoring system

TELEMETRY
get the profile results
in real time

       
       

The Datapaq Reflow Tracker Radio Telemetry system utilizes the latest radio frequency technology to allow transmission of temperature data from a Data logger in real time. As the system travels through the oven process data can be viewed, analyzed and reported instantaneously.

 

Quicker Oven Profiling
  • Compare real time data with process criteria before the system has even left the oven.
  • See immediately when problems occur, and use the information to correct them

 

A System fit for purpose
  • Licence exempt RF transmitter technology provided with full compliance to the US and European radio communications standards.
  • High-grade stainless steel barrier provides complete protection even when multiple profile runs are required.
  • Custom designed Datapaq Insight software - powerful yet easy to use.

 

Guaranteed Data Confidence
  • Automatic backup of data in logger, in addition to transmitted data received by PC
  • Auto transmission of temperature data three times minimizing interference effects and loss of data in the most hostile of environments
  • User selectable transmission frequencies providing optimum reception quality
  • Receiver signal strength meter and onboard diagnostic software make system tuning quick and efficient
  • Full graph, analysis and reporting options for traceability purposes (ISO9000/QS9000)

 

Components
 


Data Logger

Thermal Barrier

Transmitters Receivers

 



Datapaq 9000 Data Logger

With large memory capabilities these loggers are perfect where high resolution is needed or frequent readings are required.

Four logger versions – in different shapes and sizes – guarantee a fit for any electronics application, regardless of your board’s width or oven height restrictions.

Click for larger image  
  • Data retained until downloaded, can't be accidentally erased
  • Chargeable while downloading and resetting
  • Remembers previous logger settings
  • Individually calibrated channels
  • 0.1 sec sampling interval
  • Start/stop buttons
  • Line of sight LED lights
  • ~60,000 datapoints
  • Powerful and environmentally safe NiMH battery:
    - flat to useable in less than 5 minutes
    - flat to full charge in less than 2 hours
    - full charge gives over 150 runs
  • High-grade machine tooled aluminum case
  • Automatic shut-off to protect data if battery low or excessive temperatures reached

  Technical Specifications
Memory 57,342 datapoints (3ch: 28,671)
Sampling interval 0.1 sec to 10 min
Accuracy ±1°C
Resolution 0.5°C
Max internal operating temp 70°C
Data collection start Start/stop buttons, time or temperature trigger
Battery Nickel Metal Hydride (NiMH)
   
Part No. Dimensions Weight
Temperature
Range

No. of Channels
DP9061 0.45 x 4.1 x 5.9"
11.7 x 106 x 150mm
12.7 oz
0.36kg
-150 to 500 °C 6
DP9064 0.45 x 4.1 x 5.9"
11.7 x 106 x 150mm
12.7 oz
0.36kg
0 to 1,370°C 6

 

 

Thermal Barriers

Rugged, yet lightweight, these barriers withstand process oven temperatures run after run. Made of high-grade stainless steel and now with improved easy-to-use, secure button closures.

clcik for larger image
 
Time at Temperature (minutes)
Part No. Height Weight @150°C @200°C @280°C
TB2017 1"
25mm
1.9lb
0.85kg
14 11 8.5
TB2018 0.7"
18mm
1.7lb
0.75kg
8 6 3
Datapaq makes over 200 thermal barriers. Contact us with your process details to select the barrier specific to your application

 

 

 

Transmitters

 TX1001A / TX1002A
Frequency

Frequency Selection
Approvals
Effective Radiated Power
Range (open space)
Temperature Range
Humidity

US/European Transmitters
US: 464.075 to 465.875 MHz
European: 433.075 to 434.775 MHz
User selectable
EN300 220-1 and FCC
10 mW
200m / 656ft
0 to 70°C (32 to 158°F)
85% RH non-condensing

 


 

Receivers

RX1000A / RX1002A
Frequency Selection
Power
Status

US/European Receivers
User selectable to match transmitter
Via communications cable
10 segment signal strength meter

 

Due to continuing product improvements, specifications are subject to change without prior notice.

Contact Datapaq for further information.

 

Copyright 2007 Datapaq Inc.; Datapaq Ltd.

 





HomeProductsNew ProductsOven TrackerFurnace TrackerReflow TrackerKiln Tracker
Food TrackerWhat is Temperature Profiling?ServiceOrder InfoDownloads
LiteratureContactSite Map

Additional Information: Temperature MonitoringTemperature ProfilingThermal Profile
Temperature SoftwareTemperature Data LoggerHigh Temperature Data Logger
Powder Coating EquipmentReflow ProfileProcess ValidationFurnace ProfilingFurnace Control