Tpaq 21 Data Logger

Compact, highly sophisticated and accurate, this logger records 130,000 data readings over 10 selectable channels.

Variable sampling intervals and multiple event programming provides detailed analysis where heat treatment processes are followed by fast moving sections of the product temperature profile, such as gas or water quenches.

Combined with a built-in transmitter to see these processes in real
time, this is an ideal data logger for all applications
.

Highlights:

  • Ten thermocouple channels for maximum data collection on each run.
  • Huge memory capacity: 130,000 data points for detailed process analysis.
  • Sampling intervals down to 0.1 seconds to collect maximum data in minimum time.
  • High accuracy: to +/- 0.3°C / 0.5°F for compliance to tight specifications.
  • Hot data protected by non-volatile memory or software warning if reset is attempted before download.
  • USB & RS232 communication for rapid data download to laptops.
  • Radio Frequency (RF) telemetry or hard wired data acquisition for monitoring in real time with full analysis functions and alarms to alert if the process is out of specification.
  • Four status LED's to show the exact logger activity after disconnecting from the computer.
  • Push start/stop buttons for easy user control.
  • Two battery types for operation in normal and high ambient temperatures.
  • Rugged industrial case and electronics allows operation in harsh furnace and kiln environments of dust, pressure, and vacuum.
  • 'Multiple events' allows sampling interval change during the run, ideal for water and gas quench processes.
  • Reset by start button after download for speed and simplicity.

Specifications for specific thermocouple types
Type
K
N
R
S
B
J
Measuring range
-100°C – 1370°C
-148°F – 2498°F
-100°C – 1300°C
-148°F – 2372°F
-40°C – 1760°C
-40°F – 3200°F
-40°C – 1760°C
-40°F – 3200°F
55°C – 1815°C
131°F – 3300°F
0°C – 800°C
32°F – 1472°F
Accuracy
± 0.3°C / 0.5°F
± 0.4°C / 0.7°F
±1.0°C at 200°C
±1.8°F at 392°F

±0.7°C at 1000°C
±1.3°F at 1832°F
±1.0°C at 200°C
±1.8°F at 392°F

±0.8°C at 1000°C
±1.4°F at 1832°F
±1.0°C at 1500°C
±1.8°F at 2732°F

±3°C at 400°C
±5.4°F at 752°F
±0.2°C /± 0.4°F
Resolution
0.1°C / 0.2°F
0.1°C / 0.2°F
0.1°C / 0.2°F
0.1°C / 0.2°F
0.1°C / 0.2°F
0.1°C / 0.2°F

Specifications for specific logger types
Normal operating temperature High operating temperature
Model number* TP2086 TP2016 TP2186 TP2116
No. of channels 8 10 8 10
Memory (data points) 130,000 130,000 130,000 130,000
Max. operating temp. 70°C / 158°F 70°C / 158°F 110°C / 230°F 110°C / 230°F
Battery type NiMH rechargeable NiMH rechargeable VHT Lithium VHT Lithium
Max. battery life between charges** 340 hours 340 hours 250 hours 250 hours
Sampling interval:        
No telemetry
0.1 sec – 50 mins 0.1 sec – 50 mins 0.1 sec – 50 mins 0.1 sec – 50 mins
Hardwired telemetry
1 sec – 50 mins 1 sec – 50 mins 1 sec – 50 mins 1 sec – 50 mins
RF telemetry
n/a 2 secs – 50 mins n/a 3 secs – 50 mins
Max. operating pressure at 20°C / 68°F 20 bar / 290 psi 20 bar / 290 psi 20 bar / 290 psi 20 bar / 290 psi
Min. operating pressure at 20°C / 68°F 10-5millibar 10-5millibar 10-5millibar 10-5millibar
* Model number shown is for type K thermocouples only, other types have different model numbers
** Max. battery life depends on sampling interval, operating temperature and use of RF telemetry

Case size (all logger types)
Length 200 mm / 7.87"
Width 98 mm / 3.86"
Height 20 mm / 0.79"
 
General operating specifications
Logger start by: Manual (button), Temperature (rising or falling), or Time
Programmable events: Up to 8 sampling interval changes possible per run, trigger by rising or falling temperature after first event
Hot data protection: By non-volatile memory, and software warning if reset attempted before download
Communication: Via USB or RS 232 for lap top computers
Logger reset: Possible after download by start button (uses same run parameters)