Compact, highly sophisticated and accurate, this logger records 130,000 data readings over 10 selectable channels. Variable sampling
intervals and multiple event programming provides detailed analysis where
heat treatment processes are followed by fast moving sections of the product
temperature profile, such as gas or water quenches. |
|
|
The Tpaq21 is equally at home in ceramics processes such as brick and sanitaryware firing, where long duration runs at high ambient temperatures call for high memory capacity and rugged electronics. Combined with a built-in
transmitter to see these processes in real time, this is an ideal data
logger for all applications. |
|
|
Highlights:
|
|
| Specifications for specific thermocouple types | ||||||
Type |
K |
N |
R |
S |
B |
J |
Measuring range |
-100°C
1370°C -148°F 2498°F |
-100°C
1300°C -148°F 2372°F |
-40°C
1760°C -40°F 3200°F |
-40°C
1760°C -40°F 3200°F |
55°C
1815°C 131°F 3300°F |
0°C
800°C 32°F 1472°F |
Accuracy |
±
0.3°C / 0.5°F |
±
0.4°C / 0.7°F |
±1.0°C at 200°C ±1.8°F at 392°F ±0.7°C at 1000°C ±1.3°F at 1832°F |
±1.0°C at 200°C ±1.8°F at 392°F ±0.8°C at 1000°C ±1.4°F at 1832°F |
±1.0°C
at 1500°C ±1.8°F at 2732°F ±3°C at 400°C ±5.4°F at 752°F |
±0.2°C
/± 0.4°F |
Resolution |
0.1°C
/ 0.2°F |
0.1°C
/ 0.2°F |
0.1°C
/ 0.2°F |
0.1°C
/ 0.2°F |
0.1°C
/ 0.2°F |
0.1°C
/ 0.2°F |
| Specifications for specific logger types | ||||
| Normal operating temperature | High operating temperature | |||
| Model number* | TP2086 | TP2016 | TP2186 | TP2116 |
| No. of channels | 8 | 10 | 8 | 10 |
| Memory (data points) | 130,000 | 130,000 | 130,000 | 130,000 |
| Max. operating temp. | 70°C / 158°F | 70°C / 158°F | 110°C / 230°F | 110°C / 230°F |
| Battery type | NiMH rechargeable | NiMH rechargeable | VHT Lithium | VHT Lithium |
| Max. battery life between charges** | 340 hours | 340 hours | 250 hours | 250 hours |
| Sampling interval: | ||||
No
telemetry |
0.1 sec 50 mins | 0.1 sec 50 mins | 0.1 sec 50 mins | 0.1 sec 50 mins |
Hardwired
telemetry |
1 sec 50 mins | 1 sec 50 mins | 1 sec 50 mins | 1 sec 50 mins |
RF
telemetry |
n/a | 2 secs 50 mins | n/a | 3 secs 50 mins |
| Max. operating pressure at 20°C / 68°F | 20 bar / 290 psi | 20 bar / 290 psi | 20 bar / 290 psi | 20 bar / 290 psi |
| Min. operating pressure at 20°C / 68°F | 10-5millibar | 10-5millibar | 10-5millibar | 10-5millibar |
| *
Model number shown is for type K thermocouples only, other types have different
model numbers ** Max. battery life depends on sampling interval, operating temperature and use of RF telemetry |
||||
| Case size (all logger types) | |
| Length | 200 mm / 7.87" |
| Width | 98 mm / 3.86" |
| Height | 20 mm / 0.79" |
| General operating specifications | |
| Logger start by: | Manual (button), Temperature (rising or falling), or Time |
| Programmable events: | Up to 8 sampling interval changes possible per run, trigger by rising or falling temperature after first event |
| Hot data protection: | By non-volatile memory, and software warning if reset attempted before download |
| Communication: | Via USB or RS 232 for lap top computers |
| Logger reset: | Possible after download by start button (uses same run parameters) |