Type K 1.5 mm / 0.06" diameter Mineral Insulated |
|
| Probe insulation material: Max. operating temperature: Termination: Hot Junction: |
Nicrobel ‘D’ 1250°C / 2282°F Miniature plug Insulated |
|
![]() |
Type K 3.0 mm / 0.12" diameter Mineral Insulated For high temperature steel re-heat applications.The bigger diameter is less prone to shunt errors,while retaining flexibility for set-up. |
|
| Probe insulation material: Max. operating temperature: Termination: Hot Junction: |
Nicrobel ‘D’ 300°C / 572°F Miniature plug + PTFE tails Insulated |
|
![]() |
Type K ‘Nextel’ Insulated Best for low temperature applications or where fast response from open junction is needed e.g.TV tube ‘frit sealing’. No resistance to furnace atmospheres (e.g. carburising), or electrical ‘noise’. |
|
| Probe insulation material: Max. operating temperature: Termination: Hot Junction: |
Braided ‘Nextel’ fibre 1000°C / 1832°F Miniature plug Open |
|
![]() |
Type N 2.0 mm / 0.08" diameter Mineral Insulated For furnace survey applications.Type N is less susceptible to oxidation, and in some circumstances can be re-used for surveys. |
|
| Probe insulation material: Max. operating temperature: Termination: Hot Junction: |
Nicrobel ‘D’ 1250°C / 2282°F Miniature plug Insulated |
|
![]() |
Type K high temperature Glass Fibre Insulated probes |
|
| Probe insulation material: Max. operating temperature: Termination: Hot Junction: |
Glass Fibre up to 700°C / 1292°F Miniature plug Open |
|
![]() |
Type K Heavy Duty PTFE Insulated Probes For use with pressure thermal barrier in ‘wet’ or dry autoclave applications. |
|
| Probe insulation material: Max. operating temperature: Termination: Hot Junction: |
PTFE up to 265°C / 509°F Standard plug Open |
|